Water & Wastewater LIMS Software

Water and Wastewater LIMS for Drinking Water Quality and Compliance Testing Labs

A water and wastewater LIMS solution for drinking water testing, industrial wastewater analysis, and regulatory compliance. Manage samples from field to final report and support processes aligned with applicable EPA, WHO and ISO/IEC 17025 requirements.

Water LIMS Configured Around Parameters, Sampling Programmes and Decision Rules

Core Parameters and Reports for Drinking Water Quality and Wastewater Testing Laboratories

Common Parameters

  • COD (Chemical Oxygen Demand)
  • BOD (Biochemical Oxygen Demand)
  • TDS (Total Dissolved Solids)
  • pH
  • E. coli
  • Enterococci
  • Electrical Conductivity (EC)
  • Turbidity
  • Nitrate
  • Nitrite
  • Heterotrophic plate count
  • Ammonia
  • Clostridium perfringens
  • Chloride
  • Fluoride
  • Sulphate
  • Phosphate
  • Iron
  • Pseudomonas aeruginosa
  • Total coliforms
  • Manganese
  • Legionella
  • Heavy Metals (Pb, Hg, As)
  • Faecal coliforms

Lab Reports

  • Water Quality Certificate
  • Effluent Discharge Monitoring
  • Drinking Water Test Report
  • Daily Sample Log Sheets
  • Raw Data Entry Sheets
  • Microbiological Test Records
  • QC Summary Reports
  • Calibration Reports
  • Media lot QC records
  • Surface Water Analysis
  • Wastewater Compliance Forms
  • Sample Receiving Checklist
  • MPN calculation sheets
  • Internal Audit Findings
  • Nonconformity Reports
  • Corrective Action Logs
  • Lab Result Submission Forms
  • Regulatory Submission Templates
  • Trend Analysis Charts
  • Presumptive and confirmed count reports

Compliance Standards

  • ISO/IEC 17025
  • ISO 9308-1
  • ISO 7899-2
  • ISO 6222
  • Standard Methods 9221 and 9222
  • WHO Guidelines for Water Quality
  • EPA 40 CFR Part 136
  • National Regulatory Guidelines
  • State Environmental Standards
  • ISO 9001
  • Internal SOP Compliance
  • Customer-Specific QA Requirements
  • Lab Method Validation Rules
  • Traceability Requirements
  • Chain of Custody Protocols
  • Analyst Signature Requirements
  • Approved Test Method Lists
  • Retention Period Rules
  • Audit Readiness Criteria
  • QM Manual References
  • Confidentiality & Data Integrity
These cover what most water labs configure. Anything specific to your parameters or local regulations gets added during setup.
Odoo Official Partner

Connected Water Testing Laboratory Management, Powered by Odoo

Lims.science runs entirely on Odoo, a powerful ERP system trusted by over 15 million users across the world.

We’ve adapted it specifically for water and wastewater testing laboratories. Whether you’re testing drinking water quality or monitoring industrial wastewater, you’ll manage everything from parameters to compliance in one system.

 

Need Help?

FAQs

Yes. Lims.science is designed to support laboratories seeking or maintaining ISO/IEC 17025 accreditation, including features like traceable sample handling, reviewable logs and configured quality-control rules. It also aligns with guidelines from EPA, WHO, and regional environmental agencies.

Yes. Field samples are logged with GPS coordinates, collection conditions, and timestamps directly in the system. Every handoff is documented with digital signatures and custody seals, giving you a defensible chain of custody from collection point to final lab report.

Yes. Our LIMS can be configured to integrate with a broad range of laboratory instruments, including:

  • ICP-OES / ICP-MS

  • UV-Vis spectrophotometers

  • Auto-analysers

  • Online sensors and benchtop meters
    It also integrates natively with Odoo ERP, and we offer REST APIs for connecting with other platforms like SCADA, CRM, and regulatory portals.

Our Laboratory Information Management System is used by:

  • Municipal water and wastewater labs

  • Environmental monitoring agencies

  • Industrial effluent labs

  • Drinking-water quality testing labs

  • Private contract testing labs

It handles the common matrices, from influent and effluent through surface water, groundwater and treated water, for both chemical and microbiological testing.

We support all major water quality parameters, including:

  • Physico-chemical: pH, turbidity, conductivity

  • Nutrients: NH₃, NO₃, PO₄

  • Organics: BOD, COD

  • Metals: Pb, Cr, Fe, Zn

  • Microbiological: Total and faecal coliforms, E. coli, enterococci, heterotrophic plate count, Legionella and Pseudomonas. Results are held as presumptive and confirmed counts or as MPN, with the incubation period, media lot and analyst recorded against each read.

Yes. The system supports configurable parameter limits and alerts matched to local and state water regulations, generates reports configured around applicable EPA requirements and the laboratory’s ISO/IEC 17025 scope, and retains attributable, time-stamped change histories for configured result, review and approval events.

Absolutely. Whether you manage one lab or a network of facilities, our water LIMS software allows:

  • Role-based access for users across sites

  • Centralised or location-specific data control

  • Standardised SOPs and workflows

It scales from small labs to multi-country operations with ease.

Yes, and the two work differently enough that the system treats them differently. Chemistry results arrive from an instrument. Microbiology results arrive when an incubation period ends, so the workflow is built around time rather than data capture. Read windows are scheduled and flagged, presumptive and confirmed counts are held separately, and MPN values are calculated from the tube or filter pattern instead of being typed in. Media lots, control strains and sterility checks are tracked as their own records, which means a failed control can be traced to every sample it touched.

Run Chemistry and Microbiology in One Water Testing LIMS

Upgrade to a modern LIMS solution for water quality and wastewater testing. Improve turnaround time, maintain standards, and track every sample in real-time.

Scroll to Top